# VESTA-219

HR-8-F1

## Hybrid Receiver

<figure><img src="/files/w5rr3AJ71Eh1xVcD46ba" alt=""><figcaption></figcaption></figure>

## IDENTIFYING THE PARTS

<figure><img src="/files/iFILBGhZ5pUsZAugraoU" alt=""><figcaption><p>Front View</p></figcaption></figure>

<figure><img src="/files/lgBE7vlaF2GXn6aCnjgg" alt=""><figcaption><p>Side View</p></figcaption></figure>

* Pin 1 & 2 provide constant DC 12V input
  * Pin 1 is (+) polarity
  * Pin 2 is (–) polarity, Ground
* Pin 3 provides DC 12V tamper output
  * Connect a wired device; it will activate when HR receives a tamper signal from learned sensors.
  * **SW3** must be set to **ON** to include tamper as Fault output.
* Pin 4 & 5 provide an Alarm relay output
  * Connect a wired device; it will activate when HR receives an alarm signal from learned sensors.
  * SW4 selects Alarm relay behavior: Normally Closed (N.C.) or Normally Open (N.O.). See SW4 section.
* Pin 6 & 7 provide a Fault relay output
  * Connect a wired device; it will activate when HR receives a fault signal from learned sensors.
  * Fault relay is always N.C. (Normally Closed). Fault signals include Low Battery and Supervision Failure (>4 hrs).
  * SW2 must be ON to enable Supervision.

Notes:

* Tamper types include Tamper Open. (SW3 = ON to include tamper as Fault output.)

### FUNCTION SWITCH BLOCK

Open the protective cover to access a block of 6 DIP switches (marked 1–6 left to right). DIP Switch Top position = ON. Bottom = OFF.

| Switch | Function                            | ON              | OFF              |
| ------ | ----------------------------------- | --------------- | ---------------- |
| SW1    | Learning Device                     | Learning Mode   | Normal Operation |
| SW2    | Supervision                         | Enable          | Disable          |
| SW3    | Tamper Fault Output                 | Tamper included | Tamper excluded  |
| SW4    | Alarm Relay Operation               | Normal Close    | Normal Open      |
| SW5    | Relay Output Type                   | Latch           | Pulse            |
| SW6    | Test mode / Clear LED Fault Display | In Test Mode    | Normal Mode      |

Image (switch block):

<figure><img src="/files/fK9OBoFV42k59ntz5pR2" alt=""><figcaption></figcaption></figure>

#### SW1 — Learning Mode

* When SW1 = ON, LED flashes every second (learning mode).
* If an RF signal is received from a device already learned, HR emits one long beep. See "Learn-in device" section.

#### SW2 — Supervision

* Enable/disable supervision.
* If enabled (ON), lack of supervision signal from a supervised sensor (IR/SD/DC/WS) for >4 hours triggers Fault relay (Pin 6 & 7).

#### SW3 — Include Tamper as Fault

* SW3 = ON:
  * PIN 3 (DC 12V tamper output): exports 12V when tamper is received; returns 0V when restored.
  * PIN 6 & 7 (fault relay): activate on tamper according to SW5 (Latch/Pulse).
* SW3 = OFF:
  * PIN 3 always 0V on tamper.
  * PIN 6 & 7 will NOT activate on tamper.

#### SW4 — Alarm Relay NO / NC

* SW4 = ON: Alarm relay in Normal Close (loop opens when alarm occurs).
* SW4 = OFF: Alarm relay in Normal Open (loop closes when alarm occurs).
* Fault relay is always N.C. and cannot be changed.

#### SW5 — Relay Output Type

* LATCH — alarm/fault relay remains activated until condition is restored.
* PULSE — relay gives a 3-second pulse on activation.
  * Note: If alarm signal comes from an IR sensor, the relay activates as Pulse only.

Alarm & Fault examples (summary)

* Alarm outputs (Pin 4 & 5): Door Contact open, Smoke Detector trigger, Panic/WTR/RC buttons, Water detected — activate; restored when conditions clear.
* Fault outputs (Pin 6 & 7): Low battery, Supervision Failure (>4 hrs), Tamper (if SW3=ON) — activate; restored when conditions clear.

#### SW6 — Test Mode / Clear LED Fault Display

* SW6 = ON: enter Test Mode. LED flashes every 2 seconds. HR beeps 2s on each sensor signal.
* SW6 can also clear LED flash caused by fault: toggle ON then OFF to stop LED flashing. (This clears LED indicator only, not the underlying fault.)

***

## LEARN-IN DEVICES

The HR can learn up to 10 devices: PIR (IR), Smoke Detector (SD), Door Contact (DC), Water Sensor (WS), Panic Button (PB), Wrist Transmitter (WTR), Remote Control (RC).

Use the stepper below to learn devices:

{% stepper %}
{% step %}

### Step 1 — Power up

Supply 12V DC to PIN 1 & 2.

* LED will turn steady on, then HR will emit a 1-second beep.
* LED stays on in normal mode.
  {% endstep %}

{% step %}

### Step 2 — Enter Learn-in Mode

Use a sharp object to slide SW1 to ON (top).

* LED flashes rapidly once per second.
  {% endstep %}

{% step %}

### Step 3 — Send learn/test from the device

Press the device's test/learn button.

* HR emits a short beep after the sensor is learned-in.
* A long beep indicates the device was previously learned-in.
  {% endstep %}

{% step %}

### Step 4 — Repeat

Repeat Step 3 to learn additional devices (one device at a time).
{% endstep %}

{% step %}

### Step 5 — Exit Learn-in Mode

Slide SW1 to OFF (bottom) using a sharp object.

* LED stays on (normal operation).
* If 10 devices are learned, HR will warn until SW1 is switched OFF.
* Only one device can be learned at a time to prevent faulty signaling.
  {% endstep %}
  {% endstepper %}

***

## TEST MODE

Use Test Mode to verify device placement and reception.

{% stepper %}
{% step %}

### Enter Test Mode

Slide SW6 to ON. LED flashes every 2 seconds.
{% endstep %}

{% step %}

### Test a device

Hold the device in the desired location and press its test/learn button.

* HR emits a 2-second beep on receiving the sensor signal.
  {% endstep %}

{% step %}

### Repeat

Repeat for other locations/devices as needed.
{% endstep %}

{% step %}

### Exit Test Mode

Slide SW6 to OFF to return to normal operation.
{% endstep %}
{% endstepper %}

***

## NORMAL OPERATION

* LED steady ON indicates normal operation.
* When an alarm signal is received, Alarm relay (Pin 4 & 5) activates according to SW5 (Pulse or Latch).
* When a fault signal is received, Fault relay (Pin 6 & 7) activates according to SW5.
* Supervised sensors (PIR/SD/DC/WS) send supervision signals every 20–60 minutes (random). If missing >4 hrs and SW2 = ON, HR activates Fault relay.
* Tamper on PIR or DC (if SW3 = ON) causes PIN 3 to export 12V and Fault relay activation (Pin 6 & 7) per SW5.
* LED fault flash patterns:
  * Low Battery: 1 quick flash
  * Tamper: 2 quick flashes
  * Supervision: 3 quick flashes

Notes:

* To display multiple statuses, LED cycles codes at 1-second intervals.
* To clear LED fault display: Slide SW6 to ON, then back to OFF (this clears LED only, not the underlying fault).

When HR receives a test code from IR/SD/DC/WS, it beeps and flashes LED once.

***

## CLEAR DEVICE (Clear All Learned Devices)

This erases all learned sensors. After clearing, all devices must be re-learned.

{% stepper %}
{% step %}

### Step 1 — Remove power

Disconnect HR power supply.
{% endstep %}

{% step %}

### Step 2 — Set all switches to ON

Slide all DIP switches to ON (top).
{% endstep %}

{% step %}

### Step 3 — Reconnect power

Reconnect HR power.
{% endstep %}

{% step %}

### Step 4 — Confirm LED

LED will turn steady on.
{% endstep %}

{% step %}

### Step 5 — Restore switches to OFF

Slide all switches back to OFF (bottom). HR returns to Normal Operation Mode with 1-second beep and LED stays on — clearance successful.
{% endstep %}
{% endstepper %}

***

Hints and notes:

{% hint style="info" %}

* SW2 must be ON to enable Supervision.
* SW3 must be ON to include tamper as a Fault output.
* SW6 toggled ON→OFF clears LED flash but does not clear the underlying fault condition.
  {% endhint %}

If you want any section expanded into an FAQ (expandable blocks), or need the wiring diagram or relay pinouts reformatted as cards or a table for quick reference, tell me which parts you want changed.


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://vesta-guide.gitbook.io/vesta-guide/vesta-219.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.