VESTA-285
MH4936
Boiler thermostat with integrated Z-Wave

Introduction
MCO Home MH4936. Boiler thermostat with integrated Z-WAVE. Measurement of interior temperature and control of boiler heating. Remote control via Z-Wave Plus, integrated with VESTA panels. LCD display screen. Temperature setting. Tactile buttons for local control. Modern design with tempered glass. Quick connection terminals for cables. Automatic backlighting with motion sensor (PIR). Z-Wave Plus frequency: 868.42 MHz Boiler thermostat with integrated z-wave.
Main Features
Boiler thermostat with integrated Z-WAVE
Measurement of interior temperature and control of boiler heating
Remote control via Z-Wave Plus, integrated with VESTA panels
LCD display screen
Temperature setting
Tactile buttons for local control
Modern design with tempered glass
Quick connection terminals for cables
Automatic backlighting with motion sensor (PIR)
Z-Wave Plus frequency: 868.42 MHz
Power supply: 24V AC / 24V DC, 4 AA batteries
5 ~ 6 meter PIR range with 100 ° detection angle
Self-consumption: <2W
Resistive load: <1A
NTC thermistor
Wiring Diagram
REQUIRED: 24 VAC POWER (“C” WIRE)

C
AC 24 V power supply
RH
RC
WI
Is, stage heating
W2
200 stage heating or auxiliary heating
G
Fan
YI
Compressor stage I
Y2
Compressor stagc2
0/B
Changeover
K
Wire with 4-5T module
EF
Reserved terminal
Note: A wire saver acts as a splitter for applications that do not include a 24-volt C wire. If your heating/cooling system does not include a C wire,install the wire saver in or near the main unit (furnace, air handler) of your heating/cooling system.

Controlling Type

Display

Functions & Settings
Setpoint Setting Press “/\”or ” V” to set the desired indoor temperature. Setting range: 5~37 t (41~98 “F) by default.
Mode Setting This device supports OFF, HEAT, COOL, AUTO mode and EM mode (not enabled by default). Press the “MODE” button to switch the working mode.
Fan Mode Setting Short press the “FAN” key to switch the working mode of the fan.
Fan On In this mode, the fan is always running when it is turned on, and stops when it is turned off.
Fan Auto In this mode, the fan runs both in cooling and heating state ; the fan stops when cooling or heating is stopped, when the device is in shutdown state, the fan stops.
Secret Menn Under “OFF” interface, long press “MODE” button for 3 sec to enter into parameter setting interface. Short press “MODE11 button to switch the parameter number, press A “or” V “to modify the corresponding setting value, and then press “FAN” to confirm and then exit.
01
Restore factory setting
0-99
53
Default 53, change to 55 to restore factory setting
02
Device state after power failure
0- I
0 : device turn to OFF stateI: device return to last stat before power failure
04
Beep volume
1-5
I: Mute 2: Low 3:Medium 4: High 5: Normal
06
Temp. setting upper limit
1-99
37C/98F
gap I
07
Temp. setting bottom limit
0-98
5 C/41F
08
Indoor temperature calibration
-9.9-+9.9
-9.9-+9.9
09
Indoor humidity calibration
-20-+20
-20- +20
11
Temp. deadband
0-9.0
1.0 C/2.0 F
12
Temp. format
0-1
0: Celsius 1: Fahrenheit
13
Controlling type
00-07
07
Conventional cooling/heating system 0= cool only 1= heat only 2= cool or heat
Heat pump cooling/heating system
3= cool only 4= heat only 5= two stages heat 6= single cooling/single heating+ AUX
7= two stages cooling/ two stages heating+ AUX
14
Changeover valve logic
0-1
00=When the heat pump cooling starts, 0/B turned on, but turned off when heating 01=When the heat pump heating starts, 0/B turned on, but turned off when cooling
15
Compressor protection time
0-10unit: minute
Indicates the setting of compressor delay time from shutdown to startup
16
EM emergency heating mode
ON/OF
OF
ON=turn on emergency heating mode OF=turn off emergency heating mode Only available for heat pump system with heating function
Z-Wave Setting
Include into Z-Wave network Under the normal working interface, long press the” A “and” V ” buttons synchronously for 3sec, and the device will enter the Z-WAVE MENU interface, long press the” A “and” V” buttons synchronously for 3sec again or without any operation for 10sec, it will back to the homepage. Before the device is included in the network,”- – -” will display on the screen. Then shortly press the” A” button, the device will enter learning mode to get a node ID. If inclusion is a success, a node ID will display on the screen in a few seconds. Note: A node ID can always inform us whether the device is in the network or not.
Exclude from Z-Wave network Under the normal working interface, long press the” A “and” V ” buttons synchronously for 3sec, and the device will enter the Z-WAVE MENU interface, long press the” A “and” V” buttons synchronously for 3sec again or without any operation for 10sec, it will back to the homepage. Current ID displays on the screen, short press the” A” button, and the device will enter learning mode, current ID will flash, once “- – -” is displayed on the screen, the device has excluded from the Z-Wave network.
Z-WAVE supported Command Class:
Support S2:
COMMAND_ CLASS_ VERSION,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_BATTERY,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_ CLASS_SENSOR MULTILEVEL_ V5,
COMMAND_ CLASS_ THERMOSTAT_ SETPOINT,
COMMAND_ CLASS_ THERMOSTAT_ OPERATING_ STATE,
COMMAND_CLASS_THERMOSTAT_FAN_STATE,
COMMAND_ CLASS_ ASSOCIATION_ V2,
COMMAND_ CLASS_ ASSOCIATION_ GRP INFO,
Not support S2:
COMMAND_ CLASS_ THERMOSTAT_ MODE,
COMMAND_CLASS_THERMOSTAT_FAN_MODE,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_ CLASS FIRMWARE_ UPDATE_ MD_ V5
COMMAND_ CLASS_ ZWAVEPLUS _ INFO,
COMMAND_ CLASS_ SECURITY_ 2,
COMMAND_ CLASS_ TRANSPORT_ SERVICE_ V2,
COMMAND_ CLASS_ SUPERVISION
Last updated