VESTA 174

PRS2-ZBS(R)-P5 / PRM2-ZBS(R)-P5 Power Relay Switch Series

The Power Relay Switch series include the following models: PRS2-ZBS-P5: ZigBee Relay Power Switch PRS2-ZBSR-P5: ZigBee Relay Power Switch with Router function PRM2-ZBS-P5: ZigBee Relay Power Switch with Meter

PRM2-ZBSR-P5: ZigBee Relay Power Switch with Meter and Router function

The Power Switches are capable of receiving wireless signals from the coordinator in the Zigbee network to toggle On/Off of appliances that are attached to it.

The Power Relay Switch utilizes ZigBee technology for wireless signal transmission and support Over-the-Air (OTA) firmware update capability (For OTA version only). ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission.

Models with Meter functions (PRM2-ZBS-P5 / PRM2-ZBSR-P5) have the extra feature of keeping tracks of energy consumption with built-in power meter and transmit the data to coordinator regularly.

Models with router function (PRS2-ZBSR-P5 / PRM2-ZBSR-P5) also serve as a router in the ZigBee network. After being included in the ZigBee network, it allows other ZigBee device to join the network through the Power Switch.

Model No.

Meter

ZigBee Router

PRS2-ZBS-P5

No

No

PRS2-ZBSR-P5

No

Yes

PRM2-ZBS-P5

Yes

No

PRM2-ZBSR-P5

Yes

Yes

Parts Identification

1. LED indicator

The LED indicator is used to indicate Power Relay Switch status:

  • On:

The Power Relay Switch is turned on.

  • Off:

The Power Relay Switch is turned off.

  • Flashes

When the Power Relay Switch is during OTA updates.

    • Flashes twice:

The Power Relay Switch has successfully joined a ZigBee network.

    • Flashes 5 times

The Power Relay Switch has successfully bound with a controller

    • Flashes every 20 minutes

The Power Relay Switch has lost connection to its current ZigBee network

(PSS-29ZBS-P5 and PSM-29ZBS-P5 only)

  1. Function Button

Function Button Usage:

    • Press the button to toggle on/off the Power Relay Switch

    • Press and hold the button for 10 seconds then release to reset the Power Relay Switch.

    • Press and hold the button for 3 seconds then release to bind with a controller

  1. External Switch Terminal 1 (AC Voltage)

  2. External Switch Terminal 2 (AC Voltage)

  3. AC Line Power Load Output

  4. AC Neutral Power Load Output

  5. AC Neural Power Input

  6. AC Line Power Input

ZigBee Network Setup

  • ZigBee Device Guideline

1

ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and are coordinated for data exchange and signal transmission.

Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on.

  • Joining the ZigBee Network

As a ZigBee device, the Power Relay Switch needs to join a ZigBee network to receive commands and transmit energy consumption information. Please follow the steps bellow to join the Power Relay Switch into a ZigBee network.

    1. Connect the Power Relay Switch to power cable.

    2. Press and hold the Function button for 10 seconds, then release it to join the network. Please make sure the permit-to-join feature on the router or coordinator of your ZigBee network is enabled.

    3. If the Power Relay Switch successfully joins a ZigBee network, the LED Indicator will flash twice to confirm.

    4. After joining the ZigBee network, the Power Relay Switch will be registered in the network automatically. Please check the Zigbee network coordinator, system control panel or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful.

    5. If registration and joining to the network is unsuccessful, please check your ZigBee network coordinator, system control panel or CIE setting to ensure the permit-to-join function is available, and then use the Factory Reset function below to join the ZigBee network.

  • Binding with Controller

After joining the ZigBee network, the Power Relay Switch can bind itself with a controller device which can be used to adjust the Power Relay Switch’s power output level. To bind the Power Relay Switch and the device:

    1. Press and hold the Function Button for 3 seconds, then release the button. The Power Relay Switch will send binding request to the coordinator.

    2. Refer to your controller manual to send binding request for the device within 16 seconds.

    3. If binding is successful, the Power Relay Switch LED indicator will flash 5 times to confirm. You can now use the controller to adjust power output level for the Power Relay Switch.

    4. If binding is unsuccessful, please retry the binding process.

  • Removing Device from ZigBee Network (Factory Reset)

To remove the Power Switch from current ZigBee network, the Power Switch must be put to Factory Reset to complete device removal. Factory Reset function will clear the Power Switch of its stored setting and information and prompt the Power Switch to search for new ZigBee network.

Before removing device, make sure the Power Switch is within current ZigBee network signal range

    1. Press and hold the function button for 10 seconds, then release the button to reset Power Switch.

    2. Upon reset, the Power Switch will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically.

  • ZigBee Router Device Capacity (PRS2-ZBSR-P5 / PRM2-ZBSR-P5 Only)

The Power Switch models with Router function allow other ZigBee devices to join the ZigBee Network through the Router. The Power Switch Router has maximum capacity of 40 devices, including 10 routers; the Power Switch Meter Router has maximum capacity of 10 devices including 5 routers.

Model No.

Maximum ZigBee Device

Maximum ZigBee

+ Router Capacity

Router Capacity

PSS-29ZBSR-P5

40

10

PSM-29ZBSR-P5

10

5

Caution

    • All works on the device, including installation and maintenance, must be performed by a qualified and licensed electrician.

    • Before installation or any maintenance work, make sure the power supply has been disconnected.

    • Do not connect the device to loads exceeding supported load current.

    • After powering on, please avoid touching the wires to prevent electrocution.

  • OTA Firmware Upgrade (For OTA version only)

The Power Relay Switch supports OTA firmware upgrade feature via ZigBee network, which can be initiated from the ZigBee network coordinator. Follow steps below to perform OTA firmware upgrade.

  1. You have to access your ZigBee Coordinator to perform the firmware upgrade on the air.

  2. On the configuration webpage, select the device that you wish to upgrade and select the new ZigBee firmware provided. Please refer to ZigBee Coordinator User Manual for details.

  3. Press “OK” to start upgrading process, and the LED will keep flashing. During the OTA process, please do not perform any other actions, or power down the panel.

  4. The length of an upgrade will take approximately 20 to 30 minutes. Please note that the duration may 2

vary based on file size or distance between your accessory and coordinator.

  1. Wait for firmware to complete update. When the progress reaches 100%, the Device will reset automatically. You can also refresh the webpage again to ensure that the Device firmware is successfully updated with the newest version displayed.

Operation

  • Wire Connection Diagram

    • Refer to the diagram to connect your home lighting to the Power Relay Switch.

  • Installation

    • Connect the Power Relay Switch to power cable.

    • Connect the power cable to your home lighting. The lighting must be in ON status.

    • You can connect an external switch to the Power Relay Switch according to the diagram to turn on/off the Power Relay Switch

    • IMPORTANT NOTE: The Power Relay Switch does not have a backup battery and will be powered down when AC power fails. DO NOT use the Power Relay Switch as router for your security sensor or alarm control devices such as Door Contact, PIR Sensor…etc., otherwise the sensors will lose connection to ZigBee network if the Power Relay Switch is disconnected from AC power. Plan the installation locations of these security sensors without using the Power Relay Switch and only use a router with backup battery for them. The router function of the Power Switch should ONLY be used to provide signal range extension for other Power Switches/Dimmer.

  • Appliance Control

    • After the Power Relay Switch has successfully joined a ZigBee network, the coordinator can remotely turn on/off the Appliance.

    • You can also press the button on the Power Relay Switch to toggle on/off the light.

    • You can turn on/off the Power Relay Switch with an external switch.

    • If you have bound a controller with the Power Relay Switch, you can also use the controller to turn on/off the Power Relay Switch.

    • If the AC Power input is disconnected from the Power Relay Switch, its previous on/off status will be restored within 1 minute after reconnecting the AC Power input to the Power Relay Switch.

  • Energy Consumption Monitor (PRM2-ZBS-P5 / PRM2-ZBSR-P5 Only)

    • The Power Relay Switch will transmit a signal with its power consumption data every two minutes to the ZigBee network coordinator.

    • Whenever the Power Switch energy output changes by +/- 2W, it will automatically transmit a signal with power consumption data to the ZigBee network coordinator for update.

    • The Power Switch transmits a signal with power data to coordinator whenever accumulated power usage increases by 0.1kW/hr.

    • The Meter has an accuracy of +/- 5%.

    • To clear the Power Switch of its accumulated power consumption data, follow steps below:

      1. Disconnect the Power Relay Switch from power outlet.

      2. Press and hold the function button and reconnect power when holding down the button.

      3. Keep holding the button and release after 3 seconds. The accumulated power consumption data will be cleared.

  • Maximum Operation Load

    • For 110V: the maximum operation load is 1100W and 10A.

    • For 230V: the maximum operation load is 2300W and 10A.

    • If the Power Relay Switch is overheating, it will cut off power automatically as a safety measure. The user must disconnect and reconnect AC power to the Power Relay Switch after cut off to resume normal operation.

Appendix (For developers only)

Power Relay Switch with Meter Cluster ID

Device ID: Mains Power Outlet :0x0009

Endpoint:0x01

Server Side

Client Side

Mandatory

Basic (0x0000)

Identify(0x0003)

Groups(0x0004)

Scenes(0x0005)

None

3

On/Off(0x0006)

Optional

Metering (0x0702) (PRM2-ZBS-P5 / PRM2-ZBSR-P5 only)

None

Attribute of Basic Cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

ZCLVersion

Unsigned 8-bit

0x00 –0xff

Read only

0x01

M

integer

0x0001

ApplicationVersion

Unsigned 8-bit

0x00 – 0xff

Read only

0x00

O

integer

0x0003

HWVersion

Unsigned 8-bit

0x00 –0xff

Read only

0

O

integer

0x0004

ManufacturerName

Character String

0 – 32 bytes

Read only

Climax

O

Technology

0x0005

ModelIdentifier

Character String

0 – 32 bytes

Read only

(Model

O

Version)

0x0006

DateCode

Character String

0 – 16 bytes

Read only

O

0x0007

PowerSource

8-bit

0x00 –0xff

Read only

M

0x0010

LocationDescription

Character String

0 – 32 bytes

Read / Write

O

0x0011

PhysicalEnvironment

8-bit

0x00 –0xff

Read / Write

0x00

O

0x0012

DeviceEnabled

Boolean

0x00 –0x01

Read / Write

0x01

M

Attribute of Identify Cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

IdentifyTime

Unsigned 16-bit integer

0x00 –0xffff

Read / Write

0x0000

M

Attributes of the Groups cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

NameSupport

8-bit bitmap

x0000000

Read only

-

M

Attributes of the Scenes cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

NameSupport

8-bit bitmap

x0000000

Read only

0x00

M

0x0001

CurrentScene

Unsigned 8-bit integer

0x00 – 0xff

Read only

0x00

M

0x0002

CurrentGroup

Unsigned

0x0000 –

Read only

0x00

M

16-bit integer

0xfff7

0x0003

SceneValid

Boolean

0x00 – 0x01

Read only

0x00

M

0x0004

NameSupport

8-bit bitmap

x0000000

Read only

-

M

Attribute of On/Off Cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

OnOff

Boolean

0x00 –0x01

Read only

0x00

M

Attributes of the Metering cluster Information (Reading Information Attribute Set)

Identifier

Name

Type

Range

Access

Defaul

Mandatory

t

/ Optional

0x00

CurrentSummation

Unsigned 48-bit

0x000000000000

to

Read Only

M

Delivered

Integer

0xFFFFFFFFFFFF

Attributes of the Metering cluster Information (Formatting Attribute Set)

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x00

UnitofMeasure

8-bit Enumeration

0x00 to 0xFF

Read Only

0x00

M

0x01

Multiplier

Unsigned 24-bit

0x000000 to

Read Only

1

O

Integer

0xFFFFFF

0x02

Divisor

Unsigned 24-bit

0x000000 to

Read Only

10000

O

Integer

0xFFFFFF

0x03

SummationFormating

8-bit BitMap

0x00 to 0xFF

Read Only

0xF9

M

0x04

DemandFormating

8-bit BitMap

0x00 to 0xFF

Read Only

0x93

O

0x06

MeteringDeviceType

8-bit BitMap

0x00 to 0xFF

Read Only

0x00

M

Attributes of the Metering cluster Information (Historical Attribute Set)

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x00

InstantaneousDemand

Signed 24-bit

-8,388,607 to

Read Only

0x00

O

Integer

8,388,607

4