VESTA-063
Dual technology curtain outdoor sensor

INTRUDUCTION
It creates a curtain barrier of small dimensions (about 7.5°) and has an adjustable range up to 12 m. It is made with weather-resistant materials and the container is completely watertight. Furthermore, the electronics are subjected to a tropicalization process to ensure correct operation in all conditions of humidity and temperature. It is a very stable sensor and immune to false alarms.
TECH SPECIFICATION
Coverage: 12 meters, 7.5 °
Microwave frequency: 24 GHz
Sensitivity setting: 1 MW Trimmer / 1 IR Trimmer
Working mode
Alarm relay output
Tamper
Power supply: 3V ~ 10V DC
Consumption: 8µA
Protection degree IP54
Dimensions: 37 (W) x 125 (H) x 40mm
PART IDENTIFICATION

3-10V power supply
Alarm terminal block (AL-NC, AL-NO, AL-C)
Tamper terminal block (TP-NC, TP-NO, TP-C)
Red LED: in test mode detection alarm, in stand-by detection alarm if set (Dip3)
Dip Switch
Tamper
Microwave trimmer
Yellow LED in test mode mW detection, in stand-by, low battery warning if set (Dip1)
Green LED: In test mode, Infrared detection
fixing screw
Infrared trimmer
Microwave sensor
PIR
INSTALLATION
DIP 1
ON: Low battery warning. Yellow LED flashes every 2 seconds if battery is low
DIP 2
Inhibition duration. ON long inhibition (6 minutes) otherwise 3 minutes
DIP 3
ON: Alarm signal in stand-by. The red LED lights up in case of detection even if the sensor is low consumption
DIP 4
ON: Test mode. If the dip is ON -> always in test (no inhibition, LEDs active), if OFF after 3 minutes it exits the test mode

Range test in test mode
Open the cover, set Dip4 to ON, close the cover. From this moment the LEDs are always active and the sensor is no longer inhibited. Adjust the infrared and/or microwave range. Once the tests are complete, open the cover, set Dip4 to OFF and close the cover. For a further 3 minutes the sensor is in test. After this time, the sensor enters low consumption mode.
Low Battery
If the sensor is not powered by the transmitter battery, but by the internal battery (supplied separately), set Dip1 to ON. When the battery voltage drops below the preset threshold, the yellow LED flashes every (approximately) 20s.
Intrusion
By setting Dip3 to ON, the sensor activates the red LED for a few seconds each time it detects an intrusion. The signalling affects consumption by decreasing battery life. Remember that after each detection, the sensor remains inactive for at least 3-6 minutes (see Dip2).
Last updated
Was this helpful?