VESTA 373

Wireless Indoor Siren (SR-35)

SR-35 is a wireless Indoor Siren that is used for system alarm indication. When an alarm signal is received from the Control Panel, the Siren will activate to attract attention. The Siren can also work with the Control Panel to emit entry and exit delay sounds, and also alert you to tamper violation and low battery status.

The SR-35 Indoor Siren includes the following models:

SR-35 – Indoor Siren powered by two alkaline batteries

SR-35SL – Indoor Siren powered by two L91 lithium batteries

Identifying the Parts

  1. Learn Button

  2. Bottom Fixing Screw

  3. Battery Compartment

The Siren is powered by two AA L91 lithium batteries/two AA 1.5V alkaline batteries.

  1. Tamper Switch

The Tamper switch will be activated when the Siren is removed from mounting bracket.

  1. Battery Compartment Cover

  2. Mounting Bracket

Battery and Low Battery Detection

SR-35 uses alkaline or lithium batteries as its power source:

  • The SR-35 model uses two AA 1.5V alkaline batteries as its power source.

  • The SR-35SL model uses two AA L91 lithium batteries as its power source.

SR-35 features low battery detection and will transmit low battery signals when low battery voltage is detected.

When changing the batteries, after removing the used batteries, press the Tamper Switch a couple times to fully discharge before inserting new batteries.

1

  • Use only the specified batteries with the device. When replacing batteries, always replace the whole set and do not mix different types of batteries or new and used ones to avoid damaging the device.

Supervision

The Siren will transmit a supervisory signal every 30-50 minutes in normal operation mode. If this signal is not received, the Control Panel will indicate that the particular Siren is experiencing an out-of-order problem.

Function Overview

  • Alarm Memory

If an alarm was triggered in your absence and the system was not disarmed before alarm length expiry, the Siren will sound a short alarm when the system is disarmed to warn the user that an alarm has been triggered when he is away. This suggests that the intruder could still be within the premises.

  • Alarm Length

When an alarm is activated by the Control Panel, the Control Panel will notify the Siren to start alarming according to the panel’s alarm length setting. When the Panel’s alarm length expires, it will notify the Siren to stop the alarm.

If the Siren does not receive the signal from the Control Panel to stop the alarm, it will sound the alarm for a maximum of 15 minutes, and then stop the alarm.

For example:

    • If the Panel’s alarm length is set to more than 15 minutes, after an alarm is activated, instead of waiting the panel’s alarm length to expire, the Siren will stop alarming after 15 minutes.

    • If the panel is under disarmed mode and the Siren tamper switch is triggered, the Siren will not activate the alarm since the panel is under disarmed mode, and will activate the alarm for 15 minutes due to tamper triggering.

  • Siren Tamper

The Siren is protected against any attempts to open the lid or to detach the Siren from its mounting surface.

If the Siren detects a tamper condition, it will activate the siren for the programmed alarm length. A tamper signal will be sent to the Control Panel along with regular signal transmissions for the Control Panel to display the status accordingly. If the tamper condition continues, the Siren will sound a series of five beeps either every time the system is armed or when the tamper is enabled, to indicate a fault.

The tamper feature can be disabled temporaily from the Control Panel using the Siren Tamper control function. The Siren will stop tamper detection temporarily for one hour. This function is mainly designed for replacing the batteries or changing the installation location. After one hour, the Control Panel will automatically turn the function back ON. The tamper detection can also be enabled again manually using the Siren Tamper control function.

  • Audio Status Indication

While arming / disarming the system, the Siren uses different methods to distinguish various statuses for the user, as listed in the table below.

  • The Siren’s Audio indication will be affected by the Confirmation ON / OFF setting. When setting Confirmation to OFF, the confirmation sound will not be available. Refer to the Control Panel’s Siren Setting for Confirmation function.

Getting Started

  • Learning

To learn the Siren into the Control Panel, the Siren must be in Tamper Open state.

Step 1: Unscrew the bottom screw of the Siren with a Phillips screwdriver and remove the back cover.

Step 2: Put the Control Panel in learning mode (refer to the Control Panel’s user manual for details).

2

Step 3: Insert batteries to power on the Siren. The buzzer will emit 1 beep.

Step 4: Press the Learn button once. The Siren will emit a short beep. The Siren is now in learning mode and will transmit a learning code to the Control Panel.

Step 5: If the Control Panel did not receive a learning code, press the learn button again (the Siren will not sound a beep this time).

Step 6: If the Control Panel receives the learning code, it will list the device information accordingly, and please follow the instructions on the Control Panel’s user manual to complete the learning procedure. An acknowledgement signal will be sent to the Siren. When the acknowledgment signal is received, the Siren will sound five beeps to indicate that the learning process is successful. The Siren will then leave learning mode.

Step 7: Refer to the Control Panel’s user manual and use the “Edit Device” function to check Siren Settings. You can edit the operation area, zone number, and device name for the Siren.

<NOTE>

    • If the learning process fails, please remove the Siren from the Control Panel and repeat Steps 4-7 again.

    • If the Siren does not receive the confirm code from the Control Panel within one minute, the Siren will leave learning mode. Restart learning process from Step 4.

  • Edit Siren Operation Area

Follow the instructions below to change Siren Operation Area in the Control Panel Step 1: Use the panel’s “Edit Device” function to change Siren area setting. Step 2: Press the learn button on the Siren to send a signal to panel.

Step 3: When the Siren receives the acknowledgement signal from the panel, it will emit a beep to indicate the setting is applied.

The Siren will return to normal operation.

  • Programming Sound/Siren Setting

Use the Control Panel’s “Sound/Siren Setting” webpage to set siren configuration function:

  • Tamper On/ Tamper Off

You can enable or disable all RF Sirens’ tamper protection with this function. Select to turn on or off the siren’s tamper function.

<NOTE>

  • When the tamper function is turned off, the Siren will stop tamper detection temporarity for one hour. After one hour, the Control Panel will automatically turn the function back ON if the tamper function is not turned on manually.

Individual Siren Function

Edit the device’s editing page to enter the Siren setting and information.

    • Name: Enter a name for the Siren.

    • Area: Select the area which the Siren belongs to.

    • Zone: Select the Siren zone number.

  • Attribute:

  • Permanently Bypass: If checked, the Control Panel will completely ignore all signals received from the Siren. A bypassed Siren will not be able to trigger any response, including alarm or fault from the Control Panel. All other attribute settings will also be ignored.

  • Whole Area: if checked, all the Volume, Voice and Behavior functions will be simultaneously enabled in Area 1 and Area 2.

  • Volume:

  • Alarm Sound: set the volume of the alarm sound of the Siren when alarming.

  • Full arm confirm beep: set the volume of the confirm beep sound of the Siren when the Control Panel is put into Full Arm Mode.

  • Home arm confirm beep: set the volume of the confirm beep sound of the Siren when the Control Panel is put into Home Arm Mode.

  • Disarm confirm beep: set the volume of the confirm beep sound of the Siren when the Control Panel is put into Disarm Mode.

  • Exit beeps of full arm: set exit countdown beep volume under Full Arm Mode.

  • Exit beeps of home arm: set exit countdown beep volume under Home Arm Mode.

  • Entry beeps of full arm: set entry countdown beep volume under Full Arm Mode.

  • Entry beeps of home arm: set entry countdown beep volume under Home Arm Mode.

  • Door Chime: set the volume of the Door Chime sound (Ding-Dong Sound).

  • Behavior

  • Burglar trigger in home arm: Enable or Disable whether Siren is activated when an alarm is triggered under Home 3

Arm Mode.

  • Burglar trigger in full arm: Enable or Disable whether Siren is activated when an alarm is triggered under Full Arm Mode.

  • Strobe activation: Enable or Disable Siren LED strobe activation.

  • Confirm flash: Enable or Disable Siren LED flash when the system is armed/disarmed.

  • Exit flash: Enable or Disable Siren LED flash during an exit countdown period.

  • Entry flash: Enable or Disable Siren LED flash during an entry countdown period.

  • Trigger flash: Enable or Disable the flashing from the Siren LED when alarming.

  • Alarm-in-memory sound: Enable or Disable Alarm-in-Memory sound.

  • Fault sound: Enable or Disable system fault sound.

Installation

Step 1. Find the location where the Siren is to be mounted.

Step 2. Use the mounting bracket as a template to drill 3 holes on the wall for plugs.

Step 3. Push in the plugs and fix the mounting bracket on the wall with the 3 screws.

Step 4. Mount the Siren with the hooks of the mounting bracket latched on the back cover of the Siren, and then push downwards until you hear a click sound.

<NOTE>

  • Please make sure the Siren is properly hooked onto the mounting bracket, so that the tamper switch is fully depressed.

Step 5. Check if the installation is successful by testing from the Control Panel with arming and disarming function.

Successful arming/disarming is indicated by the table provided in Audio Status Indication.

<NOTE>

  • If 5 short-beeps are noticed while arming/disarming, it means the tamper is not fully depressed. Check to ensure the tamper is properly set and then test from the Control Panel again.

Step 6. The installation is now completed.

Changing the Batteries

Step 1: Disable the Siren Tamper function on the Control Panel. The Siren will sound a beep to indicate the tamper switch is now disabled.

<NOTE>

  • The siren tamper can be turned off temporarily for the need of changing batteries (refer to the instructions on the Control Panel’s user manual for further setup). The siren tamper will be turned on automatically after 1 hour in case users forget to turn it on after battery replacement is complete.

Step 2: Remove the siren from the mounting bracket. Slide-open the battery compartment cover on the back of the device to change the batteries.

4

Step 3: Remove the used batteries and press the Tamper Switch a couple times to fully discharge.

<NOTE>

  • Only use the specified batteries with the device. When replacing the batteries, always replace the whole set; do not mix different types of batteries or new and used ones to avoid damaging the device.

Step 4: Insert new batteries into the battery compartment.

Step 5: The buzzer will emit 1 beep as the Siren is powered on.

Step 6. Re-place the battery compartment cover. Attach the siren back onto the mounting bracket.

Step 7: Enter the Control Panel’s programming webpage again to enable the Siren Tamper function again. The Siren will sound a beep to indicate the tamper switch is now activated.

Factory Reset

The Siren can be reset and the memory contents can be cleared. Whenever the Siren is removed from the Control Panel, it should be put to factory reset to clear the Control Panel’s memory; otherwise the Siren will still raise alarms if it receives alarm signals from the panel.

Step 1: Remove the Siren from the Control Panel’s device list (please refer to the Control Panel’s user manual).

Step 2: Unscrew the bottom screw of the Siren’s back cover with a Phillips screwdriver and remove the back cover. (The Siren must be in Tamper Open state for factory reset.)

Step 3: Remove the batteries.

Step 4: Press and hold the Learn Button of the Siren and insert batteries to power on the siren. Continue to hold the Learn Button for 7 seconds. Release the Learn Button when you hear 2 short beeps and a long beep. The previous parameters stored in the Siren will be cleared and it will return to normal mode.

5