RS-23ZBS Room Sensor V:R3
Introduction
RS-23ZBS is a ZigBee Room Sensor. It features both temperature and humidity detection function to monitor your home environments. The temperature and humidity information will be transmitted to the coordinator in the ZigBee network and displayed on the Room Sensor’s LCD screen.
The Room Sensor utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is reliable and has low power consumption and high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission
The Room Sensor serves as an end device in the ZigBee network. It can be included in the ZigBee network to transmit signal upon activation, but cannot permit any other ZigBee device to join the network through the Room Sensor.
Parts Identification
1. LCD Display
The LCD displays the following information:
Temperature in Farenheit / Celcius setting
Humidity RH%.
Low Battery status (icon).
LCD Backlight on: when function button is pressed.
Function Button
Press the button once to:
Send a supervision signal with temperature/humidity info Light up the LCD backlight for 10 seconds.
Press and hold for 10 seconds then release to reset the Room Sensor
Base Screw (Open/Close Cover)
When the front cover is installed on the back cover, open the cover by loosen the base screw and close it likewise.
Fahrenheit / Celcius Setting Jumper (JP1)
If the jumper link is inserted between the top 2 pins, the LCD will display the temperature in Celsius. (Factory Default)
If the jumper link is inserted between the bottom 2 pins, the LCD will display the temperature in Fahrenheit.
Battery Compartment
The Room Sensor is powered by two AA 1.5 V Alkaline batteries
Back Cover
Wall Mounting Knockouts
Features
Temperature and Humidity Detection
The Room Sensor will transmit temperature and humidity signals regularly according to setting. The factory default interval is 10 minutes.
When the temperature changes by +/- 2°C, or humidity changes +/- 10%,the Room Sensor will also transmit a signal.
The change level required to trigger signal transmission is programmable using ZigBee Configure Reporting command – Reportable Change parameter. The default values are: Temperature: 200 for 2°C.
Humidity: 1000 for 10%.
1
You can also press the Function Button once to transmit a temperature and humidity signal manually.
The temperature detection range is about -10°C - 50°C (14°F - 122°F).
The humidity detection range is about 10% - 90% RH.
Battery and Low Battery Detection
The Room Sensor uses two 1.5 V Alkaline batteries as its power source. The batteries are included in the package.
The Room Sensor feature Low Battery Detection function. When the battery voltage is low, the Room Sensor will transmit Low Battery signal to notify the user and display low battery icon on LCD.
When changing batteries, after removing the old batteries, press the Function Button twice to fully discharge before inserting new batteries.
Supervision
The Room Sensor will transmit a supervision signal along with the temperature and humidity signal to report its condition regularly. The factory default interval is 10 minutes, which can be adjusted according to setting.
ZigBee Network Setup
ZigBee Device Guideline
ZigBee is a wireless communication protocol that is reliable and has low power consumption and high transmission efficiency. Based on IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission.
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on. Since performing a task in connecting network may consume some power, it is required to follow the instructions to avoid draining battery of a ZigBee device
Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee device.
Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is in use.
Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery from a ZigBee device.
Joining the ZigBee Network
As a ZigBee device, the Room Sensor needs to join a ZigBee network to transmit temperature and humidity signal. Please follow the steps bellow to join the Room Sensor into the ZigBee network.
Insert the batteries into the battery compartment to power on the Room Sensor.
After powering up, press and hold the Function button for 10 seconds, then release it to join the network. Please make sure the permit-join feature on the router or coordinator of your ZigBee network is enabled.
If the Room Sensor successfully joins a ZigBee network, the ZigBee network connectivity icon will be displayed on the LCD
After joining the ZigBee network, the Room Sensor will be registered in the network automatically. Please check your ZigBee coordinator, system control panel or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful.
After joining network and registration is successful, if the Room Sensor loses connection with the Control Panel or the Control Panel is powered down, the ZigBee network connectivity icon on the LCD on the Room Sensor will go off in 1 or 2 minutes time.
If network joining and registration is unsuccessful, the ZigBee network connectivity icon will not be displayed. Please check your ZigBee network coordinator, control panel or CIE setting to ensure the permit-join function is available, and then use the Factory Reset function below to join the ZigBee network.
Removing Device from ZigBee Network (Factory Reset)
To remove the Room Sensor from current ZigBee network, the device must be put to Factory Reset to complete device removal. Factory Reset function will clear the device of its stored setting information and prompt the Room Sensor to search for new ZigBee network.
Before removing device, make sure the Room Sensor is within current ZigBee network signal range
Press and hold the function button for 10 seconds, then release the button to reset Room Sensor.
Upon reset, the Room Sensor will clear current ZigBee network setting and transmit signal to
2
ZigBee coordinator to remove itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically.
Installation
Mounting the Room Sensor
For best LCD display quality, the Room Sensor should be mounted at location about 5° above eye level height.
Screw mounting.
When mounting with screw, make sure to only use screws provided in the package by original manufacturer, as inappropriate screws may damage interior of the device.
Remove the front cover by using a screwdriver.
Break through the knockouts on the back cover.
Using the holes as a template, drill holes in the surface
Insert the wall plugs if fixing into plaster or brick
Screw the back cover into the wall plugs
Screw the front cover back on to the back cover.
Using Room sensor with ZigBee Router
IMPORTANT NOTE
If the Room sensor installation location is away from your system control panel and requires ZigBee routers to improve signal strength. DO NOT use a ZigBee Router without backup battery. A ZigBee router without battery will be powered down during AC power failure and the Room sensor connected to the router will lose connection with ZigBee network. You should plan your Room sensor installation location using only ZigBee router with backup battery.
Appendix(For developers only.)
Room Sensor Cluster ID
Device ID: Temperature Sensor 0x0302
Endpoint: 0x01
Server Side
Client Side
Mandatory
Basic (0x0000)
None
Identify(0x0003)
Optional
Power Configuration(0x0001)
None
Temperature Measurement(0x0402)
Relative Humidity Measurement(0x0405)
Attribute of Basic Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
ZCLVersion
Unsigned
0x00 –0xff
Read only
0x01
M
8-bit integer
0x0001
ApplicationVersion
Unsigned
0x00 –0xff
Read only
0x00
O
8-bit integer
0x0003
HWVersion
Unsigned
0x00 –0xff
Read only
0
O
8-bit integer
0x0004
ManufacturerName
Character
0 – 32 bytes
Read only
Climax
O
String
Technology
0x0005
ModelIdentifier
Character
0 – 32 bytes
Read only
(Model
O
String
Version)
0x0006
DateCode
Character
0 – 16 bytes
Read only
O
String
0x0007
PowerSource
8-bit
0x00 –0xff
Read only
M
0x0010
LocationDescription
Character
0 – 32 bytes
Read /
O
String
Write
0x0011
PhysicalEnvironment
8-bit
0x00 –0xff
Read /
0x00
O
Write
3
0x0012
DeviceEnabled
Boolean
0x00 –0x01
Read /
Write
0x01
M
Attribute of Identify Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
IdentifyTime
Unsigned
0x00 –0xffff
Read /
0x0000
M
16-bit integer
Write
Attribute of Power Configuration Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0035
BatteryAlarmMask
8-bit bitmap
0000 000x
Read /
0000 0000
O
Write
Attribute of Temperature Measurement Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
MeasuredValue
Signed 16-bit
MinMeasuredValue to
Read
0x00
M
Integer
MaxMeasuredValue
only
0x0001
MinMeasuredValue
Signed 16-bit
0x954d – 0x7ffe
Read
-1000
M
Integer
only
(-10℃)
0x0002
MaxMeasuredValue
Signed 16-bit
0x954e – 0x7fff
Read
5000
M
Integer
only
(50℃)
0x0003
Tolerance
Unsigned 16-bit
0x0000 – 0x0800
Read
100
O
Integer
only
(1℃)
Attribute of Relative Humidity Measurement Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
MeasuredValue
Unsigned 16-bit
MinMeasuredValue to
Read
M
Integer
MaxMeasuredValue
only
0x0001
MinMeasuredValue
Unsigned 16-bit
0x0000 – 0x270f
Read
0
M
Integer
only
(0%)
0x0002
MaxMeasuredValu
Unsigned 16-bit
0x0001 – 0x2710
Read
10000
M
e
Integer
only
(100%)
0x0003
Tolerance
Unsigned 16-bit
0x0000 – 0x0800
Read
200
O
Integer
only
(2%)
4
ZigBee network connectivity ( icon).