VCP-LTE-SV Quick Start Guide
1. Package Content
Voice Call Point A power supply (DC 9V 1A SPS adaptor) A Wall Mounting Bracket
2. Identifying the Parts
▼ Front View ▼ Side View ▼ Back View
LED Indicator (Red) LED Indicator (Green)
Speaker
Microphone
Alarm Button
DC Jack
Battery
Switch
Micro USB Jack Nano SIM Card Slot
Component
Behavior
Condition
Alarm Button
Press once
- To make an emergency call / activate alarm.
- To answer an incoming call.
Press and hold for 5 seconds.
- To cancel the alarm.
- To terminate the call.
Press and hold for 8 seconds.
- To transmit a learn code to the Control Panel.
LED Indicator (Green)
Light on
AC Power on
Flashes once every 5 seconds
AC Fail
LED Indicator (Red)
Flashes once every 3 seconds:
Low Battery.
Flashes once every 5 seconds:
GSM fault.
3. Power Supply
A DC 9V 1A SPS power adapter is provided for AC power connection.
In addition to the AC power adapter, a rechargeable battery is installed inside VCP-LTE-SV to serve as a backup in case of a power failure.
You need to switch the battery switch to ON for the battery to be charged when AC power is connected and serve as a backup power source when AC power is missing.
4. Hardware Installation
Insert SIM card
• It is recommended to disable the SIM card PIN code before inserting into the VCP-LTE-SV.
• The SIM card base is located on the back side of the unit.
• Push to the furthest extend, then press on the edge of the SIM card firmly to secure it.
• SIM Card will delete its SMS messages whenever the VCP-LTE-SV is powered on.
Note >
Only a Nano SIM card can fit in the SIM card slot. If you don’t have the right SIM card size, please contact your service provider for a replacement of SIM card.
Do not insert a SIM card with a SIM card adapter or it will cause damage to the SIM card and its holder.
1
Wall Mounting
Step 1. Break through the 2 knockouts on the Wall Mounting Bracket.
Step 2. Use the 2 holes as a template to mark off the holes’ positions, making sure that the triangle symbol on the bracket points straight up.
Step 3. Drill 2 holes and screw the bracket onto the wall.
Step 4. Connect a DC 9V 1A SPS power adapter to the DC jack of VCP-LTE-SV and keep the cable well-placed.
Step 5. Fit VCP-LTE-SV onto the mounting bracket. Make sure the imprinted mark on VCP-LTE-SV is aligned with the upper mark on the bracket.
Step 6. Rotate VCP-LTE-SV clockwise to the lock position.
Surface Placement
Step 1. Clean the back of VCP-LTE-SV with degreaser. Connect a DC 9V 1A SPS power adapter to the DC jack and keep the cable well-placed to the right or left.
Step 2. Remove the protective cover of Anti-Slip pad and apply to the back of VCP-LTE-SV.
Step 3. Place VCP-LTE-SV at the desired location.
5. Software Installation
VCP-LTE-SV can be programmed via USB port connection of a computer using the PC Programming Tool software (with the Programming Cable). The USB Driver must be installed first for your computer to recognize the USB connection. Please go to http://www.ftdichip.com/Drivers/VCP.htm to download and install the driver according to your operation system.
Power on your PC and follow the steps below to install the firmware.
Enter https://www.climax.com.tw/climax-download-vcp-lte-sv.html in the address bar.
Download the PC programming Tool (MobileTool).
For more detailed instruction, please download “ VCP-LTE-SV Voice Call Point Installation Guide ”.
https://www.climax.com.tw/climax-download-vcp-lte-sv.html
2 2023-03-15
ON
ON
Open position
Lock position