PSS-29ZBS(R) / PSM-29ZBS(R) Power Switch Series

Introduction

The Power Switch series include the following models:

PSS-29ZBS: ZigBee Power Switch

PSS-29ZBSR: ZigBee Power Switch with Router function

PSM-29ZBS: ZigBee Power Switch with Meter

PSM-29ZBSR: ZigBee Power Switch with Meter and Router function

The Power Switches are capable of receiving wireless signals from the coordinator in the ZigBee network to toggle On/Off of appliances that are attached to it.

The Power Switch utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission.

Models with Meter functions (PSM-29ZBS / PSM-29ZBSR) have the extra feature of keeping tracks of energy consumption with built-in power meter and transmit the data to coordinator regularly.

Models with router function (PSS-29ZBSR / PSM-29ZBSR) also serve as a router in the ZigBee network. After being included in the ZigBee network, it allows other ZigBee device to join the network through the Power Switch.

Model No.

Meter

ZigBee Router

PSS-29ZBS

No

No

PSS-29ZBSR

No

Yes

PSM-29ZBS

Yes

No

PSM-29ZBSR

Yes

Yes

Parts Identification

1. Function Button aka LED indicator

The Function Button also doubles as the LED Indicator. The function button is used to control the Power Switch. The LED indicator is used to indicate Power Switch status.

LED Indication:

The LED indicator lights up in the following conditions:

  • On:

The Power Switch is turned on.

  • Off:

The Power Switch is turned off.

  • Flashes twice:

The Power Switch has successfully joined a ZigBee network.

  • Flashes 5 times

The Power Switch has successfully bound with a controller

  • Flashes every 20 minutes

The Power Switch has lost connection to its current ZigBee network

(PSS-29ZBS and PSM-29ZBS only)

Function Button Usage:

  • Press the button to toggle on/off the Power Switch

  • Press and hold the button for 10 seconds then release to reset the Power Switch.

  • Press and hold the button for 3 seconds then release to bind with a controller.

Type F Type B

Type L Type J

1

ZigBee Network Setup

  • ZigBee Device Guideline

ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and are coordinated for data exchange and signal transmission.

  • Joining the ZigBee Network

As a ZigBee device, the Power Switch needs to join a ZigBee network to receive commands and transmit energy consumption information. Follow the steps bellow to join the Power Switch into a ZigBee network.

    1. Plug in the Power Switch into a power outlet.

    2. Press and hold the function button for 10 seconds as the Power Switch resets and starts searching for existing ZigBee network. Please make sure the permit-to-join feature on the router or coordinator of your ZigBee network is enabled.

    3. If the Power Switch successfully joins a ZigBee network, the LED Indicator will flash twice to confirm.

    4. After joining the ZigBee network, the Power Switch will be registered in the network automatically. Please check the ZigBee network coordinator, system control panel or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful.

    5. If registration and joining to the network is unsuccessful, please check your ZigBee network coordinator, system control panel or CIE setting to ensure the permit-to-join function is available, and then use the Factory Reset function below to join the ZigBee network.

  • Binding with Controller

After joining the ZigBee network, the Power Switch can bind itself with a controller device which can be used to turn on/off the Power Switch. To bind the Power Switch and the device:

    1. Press and hold the Function Button for 3 seconds, then release the button. The Power Switch will send binding request to the coordinator.

    2. Refer to your controller manual to send binding request for the device within 16 seconds.

    3. If binding is successful, the Power Switch LED indicator will flash 5 times to confirm. You can now use the controller to adjust power output level for the Power Switch.

    4. If binding is unsuccessful, please retry the binding process.

  • Removing Device from ZigBee Network (Factory Reset)

To remove the Power Switch from current ZigBee network, the Power Switch must be put to Factory Reset to complete device removal. Factory Reset function will clear the Power Switch of its stored setting and information and prompt the Power Switch to search for new ZigBee network.

Before removing device, make sure the Power Switch is within current ZigBee network signal range

    1. Press and hold the function button for 10 seconds, then release the button to reset Power Switch.

    2. Upon reset, the Power Switch will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically.

  • ZigBee Router Device Capacity (PSS-29ZBSR / PSM-29ZBSR Only)

The Power Switch models with Router function allow other ZigBee devices to join the ZigBee Network through the Router. The Power Switch Router has maximum capacity of 40 devices, including 10 routers; the Power Switch Meter Router has maximum capacity of 10 devices including 5 routers.

Model No.

Maximum ZigBee Device

Maximum ZigBee

+ Router Capacity

Router Capacity

PSS-29ZBS

40

10

PSM-29ZBSR

10

5

Operation

  • Installation

    • Plug the Power Switch into a power outlet, then Plug the appliance into the socket of the Power Switch. The appliance must be in ON status.

    • IMPORTANT NOTE: The Power Switch does not have a backup battery and will be powered down when AC power fails. DO NOT use the Power Switch as router for your security sensor or alarm control devices such as Door Contact, PIR Sensor…etc., otherwise the sensors will lose connection to ZigBee network if the Power Switch is disconnected from AC power. Plan the installation locations of these security sensors without using the Power Switch and only use a router with backup battery for them. The router function of the Power Switch should ONLY be used to provide signal range extension for other Power Switches/Dimmer.

2

    • After the Power Switch has successfully joined a ZigBee network, the coordinator can remotely turn on/off the Power Switch to control the appliance

    • You can also press the button on the Power Switch to toggle its on/off status

    • If you have bound a controller with the Power Switch, you can also use the controller to turn on/off the Power Switch.

    • If the Power Switch is removed from power outlet, after re-plugging the Power Switch, its previous on/off status will be restored within 1 minute.

  • Energy Consumption Monitor (PSM-29ZBS / PSM-29ZBSR Only)

    • Power Switch models with built-in meter will transmit a signal with its power consumption data every 10 minutes to the ZigBee network coordinator.

    • Whenever the Power Switch energy output changes by +/- 2W, it will automatically transmit a signal with power consumption data to the ZigBee network coordinator for update.

    • The Power Switch transmits a signal with power data to coordinator whenever accumulated power usage increases by 0.1kW/hr.

    • The Meter has an accuracy of +/- 5%.

    • To clear the Power Switch of its accumulated power consumption data, follow steps below:

      1. Unplug the Power Switch from power outlet.

      2. Press and hold the function button and plug in the Power Switch again when holding down the button.

      3. Keep holding the button and release after 3 seconds. The accumulated power consumption data will be cleared.

  • Maximum Operation Load

    • For 110V: the maximum operation load is 1760W and 16A.

    • For 230V: the maximum operation load is 3680W and 16A.

    • If the Power Switch is overheating, It will cut off power automatically as a safety measure. The Power Switch must be unplugged and re-plugged after cut off to resume normal operation.

Appendix (For developers only)

Power Switch Cluster ID

Device ID: Mains Power Outlet :0x0009

/ SMART_PLUG : 0x0051

Endpoint:0x01

Server Side

Client Side

Mandatory

Basic (0x0000)

Identify(0x0003)

On/Off(0x0006)

Groups(0x0004)

Scenes(0x0005) (PSS-29ZBS / PSS-29ZBSR Only)

Metering(0x0702)(PSM-29ZBS /PSM-29ZBSR Only)

Optional

Groups(0x0004)

None

None

  • Attribute of Basic Cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

ZCLVersion

Unsigned

0x00 –0xff

Read only

0x01

M

8-bit integer

0x0001

ApplicationVersion

Unsigned

0x00 –0xff

Read only

0x00

O

8-bit integer

0x0003

HWVersion

Unsigned

0x00 –0xff

Read only

0

O

8-bit integer

0x0004

ManufacturerName

Character

0–32

Read only

Climax

O

String

bytes

Technology

0x0005

ModelIdentifier

Character

0–32

Read only

(Model

O

String

bytes

Version)

0x0006

DateCode

Character

0–16

Read only

O

String

bytes

0x0007

PowerSource

8-bit

0x00 –0xff

Read only

M

3

0x0010

LocationDescription

Character

0–32

Read / Write

O

String

bytes

0x0011

PhysicalEnvironment

8-bit

0x00 –0xff

Read / Write

0x00

O

0x0012

DeviceEnabled

Boolean

0x00 –

Read / Write

0x01

M

0x01

Attribute of Identify Cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

IdentifyTime

Unsigned

0x00 –0xffff

Read /

0x0000

M

16-bit integer

Write

Attributes of the Groups cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

NameSupport

8-bit bitmap

x0000000

Read only

-

M

  • Attributes of the Scenes cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

SceneCount

Unsigned 8-bit

0x00 – 0xff

Read only

0x00

M

integer

0x0001

CurrentScene

Unsigned 8-bit

0x00 – 0xff

Read only

0x00

M

integer

0x0002

CurrentGroup

Unsigned 16-bit

0x0000 – 0xfff7

Read only

0x00

M

integer

0x0003

SceneValid

Boolean

0x00 – 0x01

Read only

0x00

M

0x0004

NameSupport

8-bit bitmap

x0000000

Read only

-

M

Attribute of On/Off Cluster Information

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x0000

OnOff

Boolean

0x00 –0x01

Read only

0x00

M

Attributes of the Metering cluster Information (Reading Information Attribute

Set) (PSM-29ZBS / PSM-29ZBSR Only)

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x00

CurrentSummation

Unsigned

0x000000000000 to

Read

M

Delivered

48-bit Integer

0xFFFFFFFFFFFF

Only

Attributes of the Metering cluster Information (Formatting Attribute Set)

(PSM-29ZBS / PSM-29ZBSR Only)

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x00

UnitofMeasure

8-bit

0x00 to 0xFF

Read Only

0x00

M

Enumeration

0x01

Multiplier

Unsigned

0x000000 to

Read Only

1

O

24-bit Integer

0xFFFFFF

0x02

Divisor

Unsigned

0x000000 to

Read Only

10000

O

24-bit Integer

0xFFFFFF

0x03

SummationFormating

8-bit BitMap

0x00 to 0xFF

Read Only

0xF9

M

0x04

DemandFormating

8-bit BitMap

0x00 to 0xFF

Read Only

0x93

O

0x06

MeteringDeviceType

8-bit BitMap

0x00 to 0xFF

Read Only

0x00

M

  • Attributes of the Metering cluster Information (Historical Attribute Set) (PSM-29ZBS / PSM-29ZBSR Only)

Identifier

Name

Type

Range

Access

Default

Mandatory

/ Optional

0x00

InstantaneousDemand

Signed 24-bit

-8,388,607 to

Read Only

0x00

O

Integer

8,388,607