RSB-1ZBS
RGBW Smart Bulb
Introduction
The RSB-1ZBS is a ZigBee Smart LED Color Light Bulb. It features both multicolor adjustment and light level control. When joined into a ZigBee network, the user will be able to control Light Bulb remotely from the ZigBee network coordinator.
The Light Bulb utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is reliable and has low power consumption and high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission
The Light Bulb also serves as a route in the ZigBee network. After being included in the ZigBee network, it allows other ZigBee devices to join the network through the Light Bulb.
ZigBee Network Setup
ZigBee Device Guideline
ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission.
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on.
Ensure your ZigBee network router or coordinator is powered on before powering on the ZigBee device.
Ensure your ZigBee network router or coordinator is powered on and within range while a ZigBee device is in use.
Do not remove a ZigBee device from the ZigBee network router or coordinator without powering down the ZigBee device.
Joining the ZigBee Network
As a ZigBee device, the Light Bulb needs to join a ZigBee network to send and receive command signals. Please follow the steps below to add the Light Bulb into the ZigBee network.
Step 1. Scroll the Light Bulb into the lamp socket. Do not supply power yet.
Step 2. Enable the permit-join feature on the router or coordinator of your ZigBee network.
Step 3. Switch ON Light Bulb for 3~5 seconds. (No more than 5 seconds), then switch OFF.
Step 4. Repeat Step 3 for three (3) times for a total of four (4) ON/OFF cycles.
Step 5. Switch ON Light Bulb for the 5th time, the device will reset and start searching for new ZigBee network.
Step 6. After joining the ZigBee network, the Light Bulb will be registered in the security system in the network automatically. Please check the ZigBee network coordinator, system control panel, or CIE (Control and Indicating Equipment) to confirm if joining and registration was successful.
Removing Device from ZigBee Network (Factory Reset)
To remove the Light Bulb from current ZigBee network, the device must be placed on Factory Reset to complete device removal. Factory Reset function will clear the Light Bulb of its stored setting and information and prompt the Light Bulb to search for new ZigBee network.
Before removing device, make sure the Light Bulb is within current ZigBee network signal range
Delete the Light Bulb from current control panel / CIE.
Power off the Light Bulb.
Switch ON Light Bulb for 3~5 seconds. (No more than 5 seconds), then switch OFF.
Repeat Step 3 for 3 times for a total of 4 ON/OFF cycles
Switch ON Light Bulb for the 5th time, the device will reset and start searching for new ZigBee network.
Upon reset, the Light Bulb will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically.
1
ZigBee Router Device Capacity
The Light Bulb with Router function allows other ZigBee devices to join the ZigBee Network through the Router. The Light Bulb has a maximum capacity of 7 devices, including 4 routers.
Features
Color and Saturation Adjustment
The Light Bulb’s color and saturation may be adjusted from the ZigBee Coordinators remotely by sending commands.
Light Level Adjustment
The Light Bulb has dimmable lighting, the light percentage maybe adjusted from the ZigBee Coordinators remotely by sending commands.
Supervision
The Light Bulb will transmit a supervision signal to report its condition regularly according to user setting. The factory default interval is 10 minutes.
Appendix (For developers only)
Light Bulb Cluster ID
Device ID: Color_Dimmable_Light: 0x0102
Endpoint: 0x01
Server Side
Client Side
Mandatory
Basic (0x0000)
None
Identify(0x0003)
Groups(0x0004)
Scenes(0x0005)
OnOff(0x0006)
Level Control(0x0008)
Color Control(0x0300)
Optional
None
None
Report Cluster
On/Off (0x0006)
Report Attribute
ATTRID_ON_OFF (0x0000)
Datatype
ZCL_DATATYPE_BOOLEAN
minReportInt
0
maxReportInt
default value: 0x258 sec (600 sec)
Report Cluster
Level Control (0x0008)
Report Attribute
ATTRID_LEVEL_CURRENT_LEVEL (0x0000)
Datatype
ZCL_DATATYPE_UINT8
minReportInt
0
maxReportInt
default value: 0x258 sec (600 sec)
Report Cluster
Color Control (0x0300)
Report Attribute
ATTRID_LIGHTING_COLOR_CONTROL_CURRENT_HUE (0x0000)
Datatype
ZCL_DATATYPE_UINT8
ATTRID_LIGHTING_COLOR_CONTROL_CURRENT_SATURATION (0x0001)
Datatype
ZCL_DATATYPE_UINT8
ATTRID_LIGHTING_COLOR_CONTROL_COLOR_TEMPERATURE (0x0007)
Datatype
ZCL_DATATYPE_UINT16
minReportInt
0
maxReportInt
default value:0x258 sec (600 sec)
2
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
ZCLVersion
Unsigned 8-bit
0x00 –0xff
Read only
0x01
M
integer
0x0003
HWVersion
Unsigned 8-bit
0x00 –0xff
Read only
0
O
integer
0x0004
ManufacturerName
Character
0 – 32 bytes
Read only
Climax Technology
O
String
0x0005
ModelIdentifier
Character
0 – 32 bytes
Read only
SLCB_00.00.03.01
O
String
TC
0x0006
DateCode
Character
0 – 16 bytes
Read only
20170124
O
String
0x0007
PowerSource
8-bit
0x00 –0xff
Read only
M
Enumeration
0x0010
LocationDescription
Character
0 – 32 bytes
Read/Write
O
string
0x0011
PhysicalEnvironment
8-bit
0x00 –0xff
Read/Write
0x00
O
Enumeration
0x0012
DeviceEnabled
Boolean
0x00 –0x01
Read/Write
0x01
M
Attribute of Identify Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory /
Optional
0x0000
IdentifyTime
Unsigned
0x00 –0xffff
Read / Write
0x0000
M
16-bit integer
Attribute of Group Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory /
Optional
0x0000
NameSupport
8-bit bitmap
X0000000
Read only
-
M
Attribute of Scenes Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
SceneCount
Unsigned 8-bit integer
0x00 – 0xff
Read only
0x00
M
0x0001
CurrentScene
Unsigned 8-bit integer
0x00 – 0xff
Read only
0x00
M
0x0002
CurrentGroup
Unsigned 16-bit integer
0x0000 – 0xfff7
Read only
0x00
M
0x0003
SceneValid
Boolean
0x00 – 0x01
Read only
0x00
M
0x0004
NameSupport
8-bit bitmap
X0000000
Read only
-
M
Attribute of On/Off Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory /
Optional
0x0000
OnOff
Boolean
0x00 – 0x01
Read Only
0x00
M
Attribute of Level Control Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
CurrentLevel
Unsigned 8-bit integer
0x00 – 0xff
Read only
0x00
M
Attribute of Color Control Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
CurrentHue
Unsigned
0x00 – 0xff
Read only
0x00
M
8-bit integer
0x0001
CurrentSaturation
Unsigned
0x00 – 0xfe
Read only
0x00
M
8-bit integer
0x0007
ColorTemperatureMireds
Unsigned
0x0000 –
Read only
0x00fa (4000K)
M
16-bit integer
0xfeff
0x0008
ColorMode
8-bit
0x00 – 0x02
Read only
0x01
M
enumeration
3
Attribute of Basic Cluster Information